Crane & Deck Machinery

Deck crane VFD trips, hatch cover sequence faults, windlass overload, mooring winch joystick drift, provision crane limit switches.

Service available at all US ports — 24/7 worldwide. Our next available technician contacts you within 1 hour.

Crane & Deck Machinery
Symptom checklist

What we hear from the bridge.

  • Deck crane VFD F0007 overvoltage trip during boom lowering
  • Hatch cover motor single-phasing after rain ingress
  • Windlass main contactor chatter, brake coil burnt
  • Provision crane joystick zero-position drift
  • Slew limit switch chatters, hoist trips on creep
  • Mooring winch tension readout stuck at zero
Likely root causes

Where the fault usually lives.

  • VFD braking resistor open circuit, regen with no dump path
  • Salt bridge across terminal block inside motor JB
  • NDE bearing current pitting on ABB M3BP
  • Aged Bussmann fuses with degraded I²t
Equipment we bring

Calibrated test equipment, class-acceptable reports.

  • Fluke 438-II motor & drive analyser
  • Megger MIT525 5kV IR tester
  • SKF MicroVibe vibration / shock pulse
  • ABB ACS / Siemens / Yaskawa service tools
  • Druck DPI 620 for 4–20 mA loops

Reports compatible with DNV · BV · ABS · Lloyd's · TL · RINA · ClassNK · IRS.

Often needed together

Parts most often requested with this service.

  • vfd spares
  • limit switches
  • load cells
  • motor spares
FAQ

Common questions for this system.

Can we attend crane VFD faults at any US port?
Yes. We attend at all major US ports — East Coast, Gulf, West Coast — under the standard wizard flow. Engineer typically on the gangway within four to six hours of intake, faster at the largest hubs (Houston, NY/NJ, Long Beach).
Do we handle hatch cover automation as well as deck cranes?
Yes — hatch cover sequence faults, single-phasing, motor JB ingress and limit-switch chatter all fall in the same dispatch. Same kit (Fluke 438-II, Megger MIT525, ABB / Siemens / Yaskawa service tools) handles both.
How long does a typical crane VFD attendance take?
Diagnostic capture (DC bus voltage during a load-cycle, brake resistor verification) runs two to four hours. Brake resistor replacement is a further sixty to ninety minutes. Full controller replacement with commissioning is half a day.

Have a vessel calling?

Three quick questions — port, when, contact. Our next available technician will contact you within 1 hour.